本文二维码信息
二维码(扫一下试试看!)
Rapid Determination of Formaldehyde in Paper Cups by High Performance Liquid Chromatography
  
DOI:
Key Words:paper cups; formaldehyde; high performance liquid chromatography;steam distillation extraction
Fund Project:出入境检验检疫行业标准制修订计划项目(2015B186K)。
Author NameAffiliation
GUO Liqiang1,* 1. Weifang Customs, Weifang, Shandong Province, 261041 
LIU Peng2 2.Weifang Institute for Food and Drug Control, Weifang, Shandong Province, 261100 
ZHANG Xuankai3 3.Weifang NO.1 Middle School, Weifang, Shandong Province, 261205 
ZHANG Li1 1. Weifang Customs, Weifang, Shandong Province, 261041 
LI Yajing1 1. Weifang Customs, Weifang, Shandong Province, 261041 
Hits: 3163
Download times: 981
Abstract:
      A method was established for rapid determination of formaldehyde in paper cups by high performance liquid chromatography(HPLC). After extracting with steam distillation, the sample was added with 2-4-dinitrophenylhydrazine under 60℃in acidic condition for 30 min, and detected by HPLC, and an external standard method was used for quantitative analysis. The results indicated that the limit of quantitation (LOQ) for formaldehyde was 2.0 mg/kg. The range of 0.01~5.0 mg/L for formaldehyde standard had good linear relationship (r>0.9994). The average recoveries (n=6) of formaldehyde in paper cup samples at three added levels of LOQ ranged from 77.2%~95.7% with the relative standard deviations (RSDs) between 0.9%~3.1%. The method was convenient, quick and efficient, which could satisfy the demand of the determination of formaldehyde in paper cups.
View Full Text  View/Add Comment  Download reader  HTML

share